Medical & Dental Parts Machining (Swiss CNC Lathe)
Parts to the drawings of medical and dental device makers: surgical pins, trocar tips, abutments, scanbodies. 15 families, 151 types, ⌀0.8–19.6 mm. Get a quote.
Part Families

Smooth Surgical Pin
Straight-shank surgical fixation pin with double trocar-tapered tips.
⌀1.5–5 · L 68–162 mm
10 types

Trocar Tip
Single-ended three-facet trocar penetration tip with stepped grip shank.
⌀4–16 · L 43–106 mm
10 types

Bone Screw Pilot Pin
Self-tapping bone screw pilot pin with cortical thread body and tapered drilling tip.
⌀3–12 · L 33–115 mm
10 types

External Fixator Pin
External fixator pin with hex drive head and central threaded holding zone.
⌀6.4–19.6 · L 74–208 mm
10 types

Guidewire Tip
Guidewire tip head with internal threaded socket for wire coupling and atraumatic conical nose.
⌀0.8–4 · L 16–39 mm
10 types

K-Wire Driver Pin
Kirschner-wire driver pin with knurled grip band and sharp trocar point.
⌀1–4 · L 54–119 mm
10 types

Cannulated Guide Pin
Cannulated guide pin with axial bore for guidewire passage and partially threaded tapered tip.
⌀2.5–9 · L 76–180 mm
10 types

Implant Abutment
Stepped conical abutment seating on the implant, with internal threaded connection.
⌀4.5–9.2 · L 9.5–17.5 mm
10 types

Dental Pin
Slim locating pin with knurled grip zone for model and plaster work.
⌀2.2–6 · L 12–27.5 mm
11 types

Implant Analog
Laboratory analog representing the implant, with internal thread and knurled retention groove.
⌀4.5–9 · L 12–24 mm
10 types

Calibration Gauge
Tight-tolerance cylindrical gauge with stepped reference diameters for verifying measuring instruments.
⌀5–18 · L 18–42 mm
10 types

Micro Bushing
Thin-walled bored micro bearing bushing for handpieces and spindle seats.
⌀3–17 · L 5–19 mm
10 types

Abutment Screw
Hex-drive fine-thread micro laboratory screw fixing the abutment to the implant.
⌀2.8–8 · L 5.5–12 mm
10 types

Model Dowel Pin
Single conical dowel pin providing repeatable seating in removable plaster die models.
⌀2.5–7 · L 10–22 mm
10 types

Scan Body
Hex-referenced internally threaded scan body for locating implant position in digital impressions.
⌀6.4–19.6 · L 11–20.5 mm
10 types
Enter ⌀ and L to list matching variants with code and tolerance.
Search this category by sizeMedical and dental parts are dimension-critical turned components used in surgical instruments and implant systems. This category covers 15 families and 151 types, turned to the drawings of medical and dental device makers: smooth surgical pin, trocar tip, bone-screw pilot pin, external fixator pin, guidewire and K-wire driver pin, cannulated guide pin, implant abutment, abutment screw, dental pin, implant analog, calibration gauge, micro bushing, model dowel pin and scan body. Materials are chosen per application from 316L-grade stainless steel, brass, aluminium and alloy steel. Material certification and standards requirements are agreed with the customer when the order is placed. Parts are turned on the Goodway SW-20 Swiss lathe across a ⌀0.8–19.6 mm diameter band, in a single bar-fed setup; standard tolerance runs h5–h8 / H7; ±0.01 mm is targeted on critical diameters. Special geometries including cannulated bores, trocar tips and M1–M4 internal/external threads are machined to the drawing. Alongside the 151 catalog types, we machine custom parts to your drawing or sample; the process runs on a technical-drawing plus quotation flow.
One size here leaves the ordinary route: MEDA-FXP-10, 208 mm long, sits just past the machine's 207 mm single-setup limit and is produced in two setups. The rest of the 151 variants, 5–180 mm long, finish in one. Beyond plain turning they call for 40× thread turning, 23× hex flat milling, 60× axial bore, 90× taper turning, 31× knurling.
130 of the 151 variants reference a DIN or ISO standard; the tolerance classes in use are 6g, H7, h5, h6, h7, h8. The highest length-to-diameter ratio in the category belongs to MEDA-KWD-10 at L/D 54 — the slenderness a sliding-head lathe is built for.
Every part is CNC-turned to your drawing — series, small batches and custom turned parts. Send your drawing (PDF/DWG/STEP) for a quote.
Frequently Asked Questions
The catalog holds 15 families and 151 types: smooth surgical pin, trocar tip, bone-screw pilot pin, external fixator pin, guidewire and K-wire driver pin, cannulated guide pin, implant abutment, abutment screw, dental pin, implant analog, calibration gauge, micro bushing, model dowel pin and scan body. Parts are machined to the drawings of medical and dental device makers; sizes outside the catalog are made to your drawing.
Depending on application we machine 316L-grade stainless steel, brass, aluminium and alloy steel. Families such as surgical pins, trocars and abutments are mostly stainless; analogs and micro bushings are brass; scan bodies are aluminium; model dowel pins are steel. Material certification and standards requirements are agreed with the customer when the order is placed.
Standard tolerance is h5–h8 and H7; ±0.01 mm is targeted on critical diameters. The guide bushing of the Goodway SW-20 Swiss lathe keeps deflection minimal on slender, long parts. Cannulated bores are machined on request; requirements of standards such as ISO 5838 are agreed with the customer when the order is placed.
Yes. Send a technical drawing, dimensioned sketch or sample; within the ⌀0.8–19.6 mm band we make cannulated bores, conical tips, M1–M4 threads and custom profiles. The 151 catalog types are a starting point — production is largely custom work.
Pricing is quote-based, set by material, tolerance, geometry and quantity; no fixed figures are published on the site. Send your drawing by WhatsApp or e-mail and we respond with a quote and estimated lead time. We have manufactured in Düzce since 2009 and ship domestically and for export.
Related Categories
Let Us Create a Solution Tailored to Your Needs
Contact us to discuss your project; let's work out the most suitable solution together.